D07-11 Thermal Analog Gas Mass Flow Controller

The D07-11 thermal mass flow controller/flow meter utilizes the capillary heat transfer differential thermometry principle. It features an analog range and is not affected by temperature and pressure fluctuations, eliminating the need for temperature and pressure compensation to achieve accurate measurement and control of various gases. The D07-11 series is a high-pressure product developed by Huacheng Electronics, with a maximum pressure resistance of 10 MPa.

Advantages

High Withstand Voltage

The maximum working pressure can reach 10MPa.

Stable Control, High Precision, Good Repeatability

Accuracy is less than ±1%F.S., linearity is less than ±0.5%F.S., and repeatability is less than ±0.2%F.S.

Easy to Maintain

Designed to be simple, easy to use, and easy to maintain, reducing both usage and maintenance costs.

Innovation

Valve Control Technology of VCP

Valve control technology adopts a number of new achievements, collectively known as VCP technology. This structure has a small internal gas dead zone, fast valve response speed, and no hysteresis. Using VCP technology can effectively improve the flow control stability of the gas mass flow controller.

Constant Power Sensor

A novel constant-power sensor technology has been adopted, significantly improving the system's measurement accuracy and response speed.

Application Areas

Special Industry - Petrochemical Industry

Specialty Industry - Optical Fiber

Special industry - Vacuum Coating

Special Industry - Heat Treatment

Life Sciences - Environmental Protection

Life Sciences - Food Industry

Life Sciences - Bioengineering Life

Life Sciences - Healthcare

Scientific Research - Experimental Equipment

Specifications

ITEM D07-11C
Full Scale Range (0~5, 10, 20, 30, 50, 100, 200, 300, 500) SCCM
(0~1, 2, 3, 5, 10, 20, 30) SLM
Flow Control Range 2~100% of F.S.
Accuracy ±1% F.S (20, 30 SLM: ±2% F.S.)
Linearity ±0.5% F.S (20, 30 SLM: ±2% F.S.)
Repeatability ±0.2% F.S.
Response Time ≤ 10 sec
Differential Pressure ≤10 SLM (0.2 ~ 0.8) MPa (29~116 psid)
>10 SLM (0.2 ~ 0.6) MPa (29~87 psid)
Max. Operating Pressure 10 MPa (1450 psig)
Max Pressure 10 MPa (1450 psig)
Operation Temperature 5℃ ~ 45℃
Input Signal 0 V ~ +5.00 V
(Input impedance > 100K, output current ≤ 3mA)
Output Signal 0 V ~ +5.00 V
(Input impedance > 100K, output current ≤ 3mA)
Power Supply +15 V 50 mA; -15V 200 mA
Weight 1.2kg

Related Products

D07-19J Thermal Analog Gas Mass Flow Controller

Special Industry—Petrochemical Industry

Special Industry - Optical Fiber

Special Industry - Vacuum Coating

Special Industry - Heat Treatment

Life Science - Environmental Protection

Life Sciences - Food Industry

Life Sciences - Bioengineering

Life Sciences - Healthcare

Scientific Research - Experimental Equipment

The D07-19J thermal based analog gas mass flow controller/flow meter is based on the capillary heat transfer differential thermometry principle. It sets the analog range and will not deviate due to temperature and pressure fluctuations. It does not require temperature and pressure compensation to achieve precise measurement and control of various gases. The D07-19 series products are characterized by high stability and easy maintenance.

D07-23J Thermal Analog Gas Mass Flow Controller

Clean Energy - Photovoltaic

Clean Energy - Hydrogen Energy

Special Industry - Optical Fiber

Special Industry - Vacuum Coating

Special Industry - Heat Treatment

Life Sciences - Environmental Protection

Life Sciences - Food Industry

Life Sciences - Bioengineering

Life Sciences - Healthcare

Scientific Research - Experimental Equipment

The D07-23J thermal mass flow controller/meter utilizes the capillary heat transfer differential thermometry principle. It features an analog range setting and remains accurate despite fluctuations in temperature and pressure, eliminating the need for temperature and pressure compensation to achieve precise measurement and control of various gases. The D07-23 series is a high-flow analog control product developed and manufactured by Huacheng Electronics. It boasts high accuracy, easy maintenance, and high stability, and supports automatic zero calibration.

D07-60B Thermal Analog Gas Mass Flow Controller

Clean Energy - Photovoltaic

Clean Energy - Hydrogen Energy

Special Industry - Optical Fiber

Special Industry - Vacuum Coating

Special Industry - Heat Treatment

Life Sciences - Environmental Protection

Life Sciences - Food Industry

Life Sciences - Bioengineering

Life Sciences - Healthcare

Life Sciences - Analytical Instruments

Scientific Research - Experimental Equipment

The D07-60B thermal mass flow controller/flow meter uses the capillary heat transfer differential calorimetry principle. It features an analog range and is not subject to deviations caused by temperature and pressure fluctuations. Precise measurement and control of various gases can be achieved without temperature and pressure compensation. The D07-60 series products are ultra-high flow analog products developed and manufactured by Huacheng Electronics. They support a maximum flow rate of 2000 SLM and feature high stability and easy maintenance.

Contact Us

If you have any questions, please leave your detailed requirements information here, and we will be happy to serve you.

Contact Us
Security verification
Privacy Statement
Submit
%{tishi_zhanwei}%