D07-9 Thermal Analog Gas Mass Flow Controller

The D07-9 thermal mass flow controller/flow meter utilizes the capillary heat transfer differential thermometry principle. It features a settable analog range and is not susceptible to fluctuations in temperature and pressure, eliminating the need for temperature and pressure compensation while enabling precise measurement and control of various gases. The D07-9 series is a high-precision, fast-response analog product developed by Hua Cheng Electronics.

Advantages

Stable Control, Good Repeatability

Accuracy is less than ±1.5%F.S., linearity is less than ±1%F.S., and repeatability is less than ±0.2%F.S.

Stable at Zero, Insensitive to Position

Adopts a brand-new analog sensor, with horizontal calibration and support for installation in any direction.

Easy to Maintain

Designed to be simple, easy to use, and easy to maintain, reducing both usage and maintenance costs.

Innovation

Valve Control Technology of VCP

Valve control technology adopts a number of new achievements, collectively known as VCP technology. This structure has a small internal gas dead zone, fast valve response speed, and no hysteresis. Using VCP technology can effectively improve the flow control stability of the gas mass flow controller.

Constant Power Sensor

A novel constant-power sensor technology is employed. This technology utilizes a method to maintain a constant operating state of the sensor, significantly improving the system's measurement accuracy and response speed.

High Level of Domestication

Materials, components, and electronic devices are all designed with domestic production in mind, ensuring independent and controllable core technologies.

Application Areas

Clean Energy - Photovoltaic

Clean Energy - Hydrogen Energy

Specialty Industry - Optical Fiber

Special industry - Vacuum Coating

Special Industry - Heat Treatment

Life Sciences - Environmental Protection

Life Sciences - Food Industry

Life Sciences - Bioengineering

Life Sciences - Healthcare

Scientific Research - Experimental Equipment

Specifications

ITEM D07-9J  D07-9JM 
Full Scale Range (N₂) (0~20,30,50,100,150,200,250)SLM
Flow Control Range 2~100%F.S.
Accuracy ±1.5%F.S.
Linearity ±1%F.S.
Repeatability ±0.2%F.S.
Response Time ≤4sec
Differential Pressure

20,30 SLM: (0.05~0.30) MPa (7.3~43.5 psid)

 

50,150 SLM: (0.10~0.30) MPa (14.5~43.5 psid)

 

200,250 SLM: (0.15~0.30) MPa (21.8~43.5 psid)

20~100SLM: <0.02 MPa(2.9 psid)

 

>100SLM: <0.05 MPa(7.3 psid)

Max.Operating Pressure 1 MPa (145psig)
Max Pressure 3MPa
Leak  1×10 -10 Pa·m³/sec He
Operation Temperature (5~45) ℃
Input Signal

0V~+5.00V

 

(Input impedance greater than 100K, output current no more than 3mA)

Output Signal

0V~+5.00V

 

(Input impedance greater than 100K, output current no more than 3mA)

Power Supply +15V 50mA -15V 400mA
Weight 2.6 Kg 1.5 Kg

Related Products

D07-7 Thermal Analog Gas Mass Flow Controller

Special Industry - Petrochemical Industry

Specialty Industry - Optical Fiber

Special Industry - Vacuum Coating

Special Industry - Heat Treatment

Life Sciences - Environmental Protection

Life Sciences - Food Industry

Life Sciences - Bioengineering

Life Sciences - Healthcare

Scientific Research - Experimental Equipment

The D07-7 thermal mass flow controller/meter utilizes the capillary heat transfer differential thermometry principle. It features a set analog range and remains accurate despite temperature and pressure fluctuations, eliminating the need for temperature and pressure compensation to achieve precise measurement and control of various gases. The D07-7 series is a basic product from Huacheng Electronics, characterized by high stability, good repeatability, and ease of maintenance.

D07-11 Thermal Analog Gas Mass Flow Controller

Special Industry - Petrochemical Industry

Specialty Industry - Optical Fiber

Special industry - Vacuum Coating

Special Industry - Heat Treatment

Life Sciences - Environmental Protection

Life Sciences - Food Industry

Life Sciences - Bioengineering Life

Life Sciences - Healthcare

Scientific Research - Experimental Equipment

The D07-11 thermal mass flow controller/flow meter utilizes the capillary heat transfer differential thermometry principle. It features an analog range and is not affected by temperature and pressure fluctuations, eliminating the need for temperature and pressure compensation to achieve accurate measurement and control of various gases. The D07-11 series is a high-pressure product developed by Huacheng Electronics, with a maximum pressure resistance of 10 MPa.

D07-19J Thermal Analog Gas Mass Flow Controller

Special Industry—Petrochemical Industry

Special Industry - Optical Fiber

Special Industry - Vacuum Coating

Special Industry - Heat Treatment

Life Science - Environmental Protection

Life Sciences - Food Industry

Life Sciences - Bioengineering

Life Sciences - Healthcare

Scientific Research - Experimental Equipment

The D07-19J thermal based analog gas mass flow controller/flow meter is based on the capillary heat transfer differential thermometry principle. It sets the analog range and will not deviate due to temperature and pressure fluctuations. It does not require temperature and pressure compensation to achieve precise measurement and control of various gases. The D07-19 series products are characterized by high stability and easy maintenance.

Contact Us

If you have any questions, please leave your detailed requirements information here, and we will be happy to serve you.

Contact Us
Security verification
Privacy Statement
Submit
%{tishi_zhanwei}%