D07-60J Thermal Analog Gas Mass Flow Controller

The D07-60J thermal mass flow controller/flow meter uses the principle of capillary heat transfer differential calorimetry. It sets an analog range and does not lose accuracy due to temperature and pressure fluctuations; temperature and pressure compensation are not required to achieve precise measurement and control of various gases. The D07-60 series products are ultra-high flow analog products developed and manufactured by Huacheng Electronics. The maximum flow rate supports 2000 SLM, and it features high stability and easy maintenance. The D07-60J product supports automatic zero calibration.

Advantages

Extra Large Traffic

Maximum of 2000 SLM N2.

High Precision, High Stability, Fast response

Accuracy is less than ±1.5%F.S., linearity is less than ±1%F.S., repeatability is less than ±0.2%F.S., and response time is no more than 3s.

Low Zero Drift Coefficient

Temperature compensation is achieved through software and hardware implementation. Zero point: ≤±0.05% F.S./℃.

Complete Functionality

Client-side software with automatic reset, alarm, soft start, and delay functions.

International Certification

Obtained CE and RoHS certifications.

Innovation

Circuit Board Digital Core

Digital core computing enables better control and regulation, and facilitates real-time data interaction.

Constant Power Sensor

A novel constant-power sensor technology has been adopted, significantly improving the system's measurement accuracy and response speed.

Digital Sensor Compensation Technology

A digital sensor bridge balancing method is used to compensate for the sensor drive voltage and suppress temperature drift.

Application Areas

Clean Energy - Photovoltaic

Clean Energy - Hydrogen Energy

Specialty Industry - Optical Fiber

Special Industry - Vacuum Coating

Special Industry - Heat Treatment

Life Sciences - Environmental Protection

Life Sciences - Food Industry

Life Sciences - Bioengineering

Life Sciences - Healthcare

Scientific Research - Experimental Equipment

Technical indicators

ITEM D07-60J D07-60JM
Full Scale Range 300,500,750,1000,1500,2000(SLM)
Flow Control Range 2~100% of F.S.
Accuracy ± 1.5% F.S.
Linearity ±1% F.S.
Repeatability ±0.2%F.S.
Response Time < 3 sec
Differential Pressure (0.25 ~ 0.5) MPa (≤1000SLM) (36.25~72.5psid) <0.2 MPa (29psid)
(0.4 ~ 0.6) MPa (>1000SLM) (58~87psid)
Max. Operating Pressure 0.6MPa (87psig)
Max Pressure 3 MPa (435.1psig)
Operation Temperature 5~ 45 ℃
Input Signal 4~20 mA or 1~5 VDC ——
Output Signal 4~20 mA or 1~5 VDC
Power Supply +24VDC 400 mA
Weight 6  kg 5  kg

Related Products

D07-60B Thermal Analog Gas Mass Flow Controller

Clean Energy - Photovoltaic

Clean Energy - Hydrogen Energy

Special Industry - Optical Fiber

Special Industry - Vacuum Coating

Special Industry - Heat Treatment

Life Sciences - Environmental Protection

Life Sciences - Food Industry

Life Sciences - Bioengineering

Life Sciences - Healthcare

Life Sciences - Analytical Instruments

Scientific Research - Experimental Equipment

The D07-60B thermal mass flow controller/flow meter uses the capillary heat transfer differential calorimetry principle. It features an analog range and is not subject to deviations caused by temperature and pressure fluctuations. Precise measurement and control of various gases can be achieved without temperature and pressure compensation. The D07-60 series products are ultra-high flow analog products developed and manufactured by Huacheng Electronics. They support a maximum flow rate of 2000 SLM and feature high stability and easy maintenance.

D07-19J Thermal Analog Gas Mass Flow Controller

Special Industry—Petrochemical Industry

Special Industry - Optical Fiber

Special Industry - Vacuum Coating

Special Industry - Heat Treatment

Life Science - Environmental Protection

Life Sciences - Food Industry

Life Sciences - Bioengineering

Life Sciences - Healthcare

Scientific Research - Experimental Equipment

The D07-19J thermal based analog gas mass flow controller/flow meter is based on the capillary heat transfer differential thermometry principle. It sets the analog range and will not deviate due to temperature and pressure fluctuations. It does not require temperature and pressure compensation to achieve precise measurement and control of various gases. The D07-19 series products are characterized by high stability and easy maintenance.

D07-7 Thermal Analog Gas Mass Flow Controller

Special Industry - Petrochemical Industry

Specialty Industry - Optical Fiber

Special Industry - Vacuum Coating

Special Industry - Heat Treatment

Life Sciences - Environmental Protection

Life Sciences - Food Industry

Life Sciences - Bioengineering

Life Sciences - Healthcare

Scientific Research - Experimental Equipment

The D07-7 thermal mass flow controller/meter utilizes the capillary heat transfer differential thermometry principle. It features a set analog range and remains accurate despite temperature and pressure fluctuations, eliminating the need for temperature and pressure compensation to achieve precise measurement and control of various gases. The D07-7 series is a basic product from Huacheng Electronics, characterized by high stability, good repeatability, and ease of maintenance.

Contact Us

If you have any questions, please leave your detailed requirements information here, and we will be happy to serve you.

Contact Us
Security verification
Privacy Statement
Submit
%{tishi_zhanwei}%